Terminal (wire connection): Push-In Plus Terminal.
Applicable output load: DC load.
Zero cross function: --.
Rated input voltage: AC 200V.
slim I/O solid state relay.
control panel.
in comparison with conventional screw terminals.
traditional screw terminals.).
realizing high reliability.
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange.
Classification: Arc barrier equipped model.
Plug-in terminals/Solder terminals.
Highly Reliable, 4-pole Miniature Relay Ideal,
for Sequence Control.
Card lift-off employed for greater life and stable quality.
Long endurance and stable quality are assured by card lift-off system.
Mounting interchangeability with MY-series Relays OMRON G3RV-SR500-D AC200.
Operation indicator mechanism incorporated for at-a-glance,
monitoring of ON/OFF operation
G3RV-SR500-D AC200 In addition, a built-in operation,
indicator model is also included in this Relay Series. Terminal (Wire connection): Push-In Plus Terminal.
Classification: Standard.
Latching lever (Test switch): No.
Rated input voltage: AC/DC, 48V.
Global standard size, low profile slim OMRON G3RV-SR500-D AC200.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape.
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location) OMRON G3RV-SR500-D AC200.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. Input terminals: M3 terminals.
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 1 output (Heater Burnout Detection,
SSR Short-circuit Failure Detection, Common).
Applicable load (See note.): 2 to 25 A, 100 to 240 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phaase heaters G3RV-SR500-D AC200.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp termiinals (detachable), or compact slotted,
screw terminals (detachable) G3RV-SR500-D AC200.
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified.