Classification: Output (single contact), SPDT.
Rated voltage: 12 VDC, 24 VDC.
Slim-styled I/O Relay Saves Space in Panel.
SPST-NO, SPST-NC, and SPDT contact forms available for,
output (SPST-NO only for input).
Ultra-slim housing measuring 29 (W) x 10 (D) x 32 (H) mm.
All Output Relays provide a long endurance (1,000,000,
operations at 5 A), while all Input Relays provide microswitching,
power (100 μA at 1 V) G3RV-SR500-D AC100 PDF datasheet
G3RV-SR500-D AC100
Approved by UL and CSA standards. Insulation method: Phototriac.
Operation Display: Yes(green).
Output(SSR): AC.
Zero cross Function: NO.
Rated output Load: 2 A(at 100 to 240 VAC).
Rated input voltage (socket): 24 VDC, 24 VAC/VDC.
Applicable model: G3RV-SR700/500-A DC24V, G3RV-SR700/500-A AC/DC24V G3RV-SR500-D AC100 PDF datasheet.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals.
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals G3RV-SR500-D AC100 PDF datasheet. ).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. Safety outputs *1: Instantaneous, 2 (Semi conductors);
OFF-delayed*2, 2(Semiconductors).
Auxiliary outputs *3: 2 (Semi conductors).
Logical AND connection input: 1.
Logical AND connection output: 1.
Max. OFF delay time *4: 3.0 s.
Rated voltage: 24 VDC.
Terminal block type: Screw terminals.
Electronic Detection Mechanism for.
Better Stability in Non-contact Door.
Switch Operation. Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes.
Applicable output lload(See note 2 G3RV-SR500-D AC100 datasheet PDF catalog. ): 40 A at 24 to 220 VAC (at 40°C).
Rated input voltage: 5 to 24 VDC.
SSR with output (5 to 90 A) at a reasonable price
Zero cross function enables less noise operation.
Built-in varistor efffectively absorbs external surges G3RV-SR500-D AC100 datasheet PDF catalog.
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Certified by UL, CSA and TÜV.