OMRON
Home >> Products >> OMRON >> Power/other peripheral devices >> Connection / Save wiring equipment >> Connector terminal station conversion unit >> XW2Z-150BU | OMRON Connecting Cables for Connector-Terminal Block Conversion Units XW2Z-150BU

XW2Z-150BU | OMRON Connecting Cables for Connector-Terminal Block Conversion Units XW2Z-150BU

OMRON XW2Z-150BU Manual And Instructions
XW2Z-150BU datasheetPDF datasheet

OMRON XW2Z-150BU Product information and technical parameters:
Brand: OMRON
Name: Connecting Cables for Connector-Terminal Block Conversion Units
Model: XW2Z-150BU
Type: Normal wiring.
Cable length L: 1.5 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch.

Terminal/mounting: Plug-in/DIN rail via socket.
Control voltage: 200/220/240 VAC.
Overcurrent detection: Instantaneous type, W/start-up lock.
Solid-state, Plug-in Current Sensor.
Applicable to motor overcurrent protection and 3-phase AC current detection.
Inverse-type, start-up lock type, and instantaneous type over,
current sensors available OMRON XW2Z-150BU.
Instantaneous type under current sensor available XW2Z-150BU
Plug-in design simplifies installation, removal, and wiring.
DIN sized (48 mm x 96 mm). Number of inputs: 16.
Number of contacts: 20.
I/O: Inputs.
Mounted Connector model: XG4A-2031 (PLC side), XN2D-4431 (input side).
Cable Connector Model: XG4M-2030-T (PLC side), XN2A-1470 (input side).
Conversion Unit with Industrial OMRON XW2Z-150BU.
Standard e-CON Terminal Block.
Connectors.
I/O connectors for easier wiring.
Easy connections via connectors (no special tools required).
Compatible with e-CON connectors from other companies. Control power supply voltage: 200/220 VAC.
Input: DC or AC (selectable); input voltage range: 10 to 300 V: Operating mode,
ON-delay; OFF-delay; Startup lock.
Overvoltage/Undervoltage Monitoring OMRON XW2Z-150BU.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@). Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC.
(DC power cannot be input.).
Power ratings: 150 W.
Output voltage: 48 V.
Output current: 3.3 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V).
Easy Mounting: Front-mounted type, DIN rail-mounted type are available.
Screw-mount at the top. (except 300-/600-W models).
Safety standardds: UL 508/60950-1, cUL CSA C22 XW2Z-150BU. 2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA).
Input conditions: The inpuut voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply XW2Z-150BU. ).


...More relevant models >>>>