Cable specifications: Spatter-resistant Cable.
Cable length L: 2 m.
Cable outer diameter: 6.6 mm.
Straight/straight.
Minimum order: 5.
UL: --.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock.
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved.
Power ratings: 240 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*3).
Output voltage: 24 V.
Output current: 10 A.
UL Class 2 Output standards: --.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for OMRON XS5W-D421-D81-SA.
Easy System Commissioning.
New 90-W models with indication monitor that
XS5W-D421-D81-SA
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC OMRON XS5W-D421-D81-SA.
(Not compliant with EC Directives and other safety standards.) Power ratings: 120 W.
Rated input voltage: 100 to 240 VAC .
(allowable range: 85 to 264 VAC or 90 to 350 VDC).
Rated output voltage: 24 V.
Rated output current: 5 A.
Maximum boost current: 6 A.
A Perfect Fit for Small Control Panels.
Coated PCBs for Better Resistance to Environment.
Connections for Easy Wiring OMRON XS5W-D421-D81-SA.
Operation possible at ambient temperatures from -40 to 70°C.
DC input supported (90 to 350 VDC).
Power Boost function at 120%.
Horizontal side-by-side mounting.
Vibration resistance to 5G, and 300-VAC abnormal,
input voltage supported for 1 second.
Complies with EN/IEC 61558-2-16.
UL 508 Listing/UL 1310 Class 2 output standards *1,
ANSl/ISA 12.12.01.
Certification for 3,000 m altitude,
(UL/EN/IEC 60950-1 and EN 50178).
Lloyd’s, DNV GL *2.
Conforms to F47-0706.
Five years Warranty *3. Control supply voltage: 110/220 VAC; With voltage fluctuation compensation.
Operating current: 0.25 to 0.5 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out XS5W-D421-D81-SA.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with booth single-phase and three-phase heaters XS5W-D421-D81-SA.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage.