No. of cable cores: 4.
Item: Vibration-proof robot cable.
Cable connection direction: Right-angle.
Cable length L: 1 m.
Small Round Water-resistive.
Connectors.
Water-resistive, compact connector meets IP67 requirements.
S8 snap-in models that connect and disconnect with one touch.
Ideal for a wide variety of FA and OA applications.
Connectors on both cable ends require no harness work.
Some new M8 models with 3 or 5 poles.
Power rating: 200 W.
Input voltage: 100 to 120 VAC, 200 to 240 VAC (allowable range: 90 to 132 VAC,
180 to 264 VAC, or 254 to 373 VDC(Select with the switch.)*2).
Output voltage: 48 V VDC.
Output current: 4.43 A.
Built-in fan: None.
Model with terminal block facing forward.
High Reliability at a Reasonable Cost OMRON XS3F-M422-401-R.
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation
XS3F-M422-401-R
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage.
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life. A reliable 3-year warranty.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications OMRON XS3F-M422-401-R.
Global Standards: Conforms to CE (all models),
Approved for UL (all models) and CCC (15 to 150-W models).
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W. Output voltage: 24 V.
Output current: 2 OMRON XS3F-M422-401-R. 5 A.
Connector terminal Model (See note 3.): With Bus Line Connectors (See note 1 .).
Block-type Switch Mode Power Supply That.
Mounts to DIN Rail.
One model covers 30 to 120 W (12-V models).
One model covers 60 to 240 W (24-V models).
Easy creation of multi-power supply configurations with different,
output power supplies connected together (5-V, 12-V, and 24-Vmodels).
Improve power supply system reliability by creating N+1 redun,
dant systems (12-V and 24-V models).
RoHS-compliant.
Input conditions: 80 to 370 VDC supported for DC input too,
(EC Directives and safety standards are not applicable.)
Operating temperatures to –20°C (24-V models). Control supply voltage: 220 VAC; With voltage fluctuation compensation.
Operating current: 32 to 80 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out thee burned element even if one heater el,
ement among several heater elements has been burned out XS3F-M422-401-R.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with booth single-phase and three-phase heaters XS3F-M422-401-R.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage.