Shape: tension release (XG4M).
Pole number: 20.
Pole pole number: 1.
Minimum packing unit: 200.
Printed board connector core, MIL specification standard.
Through the use of new productivity design, high reliability and low price synchronization.
A box type plug (XG4C) which is convenient for saving space is provided in the province.
A press type plug (XG4E) capable of using the relay is provided.
Will be the company''s loose wire connector (XG5) - specific plug (XG8) and PCB type.
(XG2) combined use of various types of packaging can be achieved.
Suitable for the company''s own development of a simple locking lever can make the unique plug (XG8) and,
Box type plugs (XG4C) can also be locked.
MIL specification (MIL-C-83503) standard.
Standard product conforms to the UL specification (No. E103202 File) certified products.
Suitable cable dia: 6 mm dia. model (5 to 6 mm dia.).
Suitable core size: 0.5 max.
Suitable Sheath material: PVC, PE, PUR.
Cable connection direction: Straight.
Connection method: Soldering.
AC: Model.
Minimum order: 50.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort OMRON XG4T-4004.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating
XG4T-4004
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202 OMRON XG4T-4004. Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase OMRON XG4T-4004.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Measuring voltage: 20 to 200 V AC/DC, 30 to 300 V AC/DC, 60 to 600 V AC/DC.
Supply voltage: 100-115 VAC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and autoomatically resetting supported by one Relay XG4T-4004.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Process control signal (0 to 10 V) and current splitter input ssupported XG4T-4004.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply.