OMRON
Home >> Products >> OMRON >> Master slave station products >> CompoBus/S >> SRT2-OD04 | OMRON Transistor Remote I/O Terminals SRT2-OD04

SRT2-OD04 | OMRON Transistor Remote I/O Terminals SRT2-OD04

OMRON SRT2-OD04 Manual And Instructions
SRT2-OD04 datasheetPDF datasheet
SRT2-OD04 SETUP MANUAL

OMRON SRT2-OD04 Product information and technical parameters:
Brand: OMRON
Name: Transistor Remote I/O Terminals
Model: SRT2-OD04
I/O classification: Output.
Internal I/O circuit common: NPN (- common).
I/O points: 8.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC.
Long-distance Communications Supported by SRT2 Models,
(Long-distance/High-speed Communications Selection).
Ultra-compact at 80 x 48 x 50 (W x H x D) mm for,
4-point and 8-point terminals and 105 x 48 x 50,
(W x H x D) mm for 16-point terminals.
Two independent power supplies can be used,
because the I/O terminals are insulated from the internal circuits.
DIN track mounting and screw mounting are both supported.

Name: Expansion Units.
Specifications: inputs ;
8 inputs; NPN;
One Expansion Unit can be,
mounted to one CRT1-ID16(-1),
CRT1-OD16(-1), CRT1-ROS16,
or CRT1-ROF16 Digital I/O Slave.
Standards: CE, UC, UC1, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet OMRON SRT2-OD04.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system SRT2-OD04
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error OMRON SRT2-OD04. I/O classification: Counter Unit.
External I/O points: Inputs: 1, Outputs: 2.
I/O connections: Terminal block.
Operating mode: Linear counter.
A Counter Unit Supporting Encoder,
Input for Use with MULTIPLE I/O TERMINAL.
High-speed pulse with counting speed of 50 kHz.
Counting can be set to a multiplication factor of 1 or 4.
Wide range of measurement: -8,388,608 to 8,388,607 OMRON SRT2-OD04.
One external input and two external outputs are available.
DIN track mounting. Unit: Connector model.
I/O classification: Digital output.
Internal I/O common: PNP (+ common).
I/O points: 16.
I/O connections: Molex connector.
Power supplyvoltage: 24 VDC.
I/O specification: 0.5 A, DC/transistor.
Digital I/O Units Compatible with MULTIPLE I/O TERMINAL,
Terminal block, connector, and high-density connector,
models are available.
The circuit block of the terminal block model can be,
mounted or dismounted for ease of maintenance without,
disconnecting the wires.
DIN track mounting. I/O classification: Digital I/O.
Internal I/O circuit common: PNP (+ common).
I/O points: 16.
I/O connection method: M3 termiinal block SRT2-OD04.
Models with 3-tier Terminals (16 Points),
Added to the Remote I/O Terminal Series.
Six Models are Available Depending on the,
NPN or PNP Configuration, Input Points,
I/O Points, or Output Points.
Incorporates easy-to-wiree terminals each,
connecting to a single wire SRT2-OD04.
Reduces designing and wiring effort.
Incorporates a removable circuit block of cassette construction.


...More relevant models >>>>