Category: incidental cover type.
Structure: DIN guide rail mounting type.
Capacity: 150W.
Output voltage: 15V.
Output current: 10A.
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
Power failure detection function with built-in hint output voltage abnormity.
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
Open circuit: voltage, no voltage, DC circuit breaker.
Appearance: P5 shell.
Rated current: AC110V.
Rated frequency: 50/60Hz.
Consume VA: action time 5VA below.
Action current adjustment range (zero phase converter primary current):
0.1-0.2-0.3-0.4-0.6A (5 shunt).
Control output: 1C, 1A (voltage output contact);
AC 110V 7 OMRON S8VM-15015CD. 5A cos (AC 250V maximum diameter =0.4 825VA),
5000 times 24V 5A L/R=7ms DC (max 125V 25W time DC) 5000 times
S8VM-15015CD
Relay control output for circuit breaker switching.
Quality: about 0.5kg.
External: Mount Searl N1.5.
High voltage grounding relay AGF type, anti wave interference,
Arc grounding, short circuit capability, high reliability.
The anti - interference ability is strong, and can safely correspond to the arc grounding fault OMRON S8VM-15015CD.
The grounding relay and the zero phase converter ZCT can be separately used.
(any combination is not more than JIS of the specified error range, and therefore can be used)
Can carry out fine current adjustment, easy to coordinate.
In all the models set up alarm terminal.
Type: Cable with Connectors on Both Ends (RJ45/RJ45).
Category: Cat.6a OMRON S8VM-15015CD.
Cable sheath material: LSZH.
Cable color: Green.
Cable length: 15 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Standard function model: detection of under voltage.
Appearance: ADR shell.
Open circuit: voltage, no voltage, DC circuit breaker.
Rated voltage: AC110V.
Rated frequency: 50/60Hz.
Voltage adjustment range: 60-65-70-75-80-85-90V (7 shunt).
Time hopping: timing; -0.2-0.4-0.6-0.8-1.0
-1.2-1.4-1.6-1.8-2.0s (11 shunt).
Control power supply: No, and input common; there, DC operation.
Rating consumption VA: No, 6VA (input side);
Have, 2VA (input side) 10W (control power supply side).
Control: 1C, 1A AC110V 7.5Acos output with =0.4
(max 250V 825VA AC);
24V 5A L/R=7ms DC (max 125V 50W when DC).
Display: start display (LED display),
Action display (trip) manual reset.
Automatic experiment: -.
Quality: about 2kg.
External: Mount Searl N1.5.
Static voltage relay.
K2VR-S/K2VA-S type, high action reliability disk with static type UVR/OVR.
Accurate work through high reliability semiconductor circuits S8VM-15015CD.
Type K2VU-S1 is the output contact, but will be closed when the voltage is not enough,
Therefore, the locking time sequence circuit of the circuit breaker is not required.
Within thhe hidden from the start to the 2S timer, can easily adjust the time S8VM-15015CD.
The control power of the relay is not needed, which avoids the trouble of wiring.