Type: open type.
Structure: bottom mounting type.
Capacity: 100W.
Output voltage: 12V.
Output current: 8.5A.
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
Power failure detection function with built-in hint output voltage abnormity.
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
Cable: PVC.
Cable core number (core): 3.
Cable outlet direction: L type.
Cable length L:5m.
The province, province hours maintenance, use waterproof connector environment and strong tolerance of FA.
Conform to IP67. FA small special connector flame retardant 94V-0.
The connector wiring system, convenient equipment maintenance, reduce equipment downtime OMRON S8VM-10012.
IEC61076-2-101 (IEC60947-5-2)
S8VM-10012
For LED products, can clearly confirm the status of the sensor action. Control supply voltage: 100/ 200 VAC; Without voltage fluctuation compensation.
Operating current: 2 to 4 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal OMRON S8VM-10012.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage OMRON S8VM-10012. Type: S8JC-Z series models list.
Meet the criteria: No.
Configuration: power supply with cover; bottom surface mounting.
Input voltage: 150W.
Output voltage: 12VDC.
Output current: 12.5A.
Economic type power supply S8JC-Z additional models,
The new power S8JC-ZS has a CE certification mark to market.
Product features: reduce material costs;
Export machinery to be used to meet specific safety standards;
Through the DIN guide rail installation, significant savings in time. Rated voltage: 115 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.120 A; 60 Hz, 0.100 A .
Rated input: 50 Hz, 10 W ; 60 Hz, 9 W .
Rated rotational speed: 50 Hz, 2700 r/min; 60 Hz, 3200 r/min.
Maximum flow rate: 50 Hz, 0.8 m3/min; 60 Hz, 0.9 m3/min.
Maximum static pressure: 50 Hz, 42.1 Pa; 60 Hz, 58.8 Pa.
Noise: 50 Hz, 32 dB; 60 Hz, 36 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and mmetal-bladed models,
(28 type) included in series S8VM-10012.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certiffied safety standards depend on the,
product S8VM-10012. Check the information given for available models of Axial fans and,
the information in Characteristics.