Category: incidental cover with under voltage detection function.
Structure: DIN guide rail mounting type.
Capacity: 50W.
Output voltage: 24V.
Output current: 2.2A.
Alarm output: source type.
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
Power failure detection function with built-in hint output voltage abnormity.
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Cable type: Standard Cables.
Type: Cable with Plugs on Both Ends (M12 Straight/RJ45) .
Cable length: 15 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Power supply voltage: 100 to 240 VAC OMRON S8VM-05024PD.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase)
S8VM-05024PD
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload OMRON S8VM-05024PD.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads OMRON S8VM-05024PD.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Cable specifications: Oil-resistant Polyurethane Cable.
Cable length L: 10 m.
Cable outer diameter: 6 mm.
Angled Connectors.
Minimum order: 1.
UL: --.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock.
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved. Power ratings: 480 W.
Input voltage: 100 to 240 VAC.
Output voltage: 24 V.
Output current: 20 A Peak current 30 A(200 VAC).
Alarm output *2: Sinking/sourcing.
UL Class 2 Output standards: --.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Ouutput standards S8VM-05024PD.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 ((= VDE 0805 Teil 1) S8VM-05024PD.
Input conditions: DC input is also possible from 80 to 370 VDC.