Power ratings: 240 W.
Input voltage: 2-phase and 3-phase, 380 to 480 VAC, 450 to 600 VDC.
Output Voltage: 24 V.
Output current: 10 A.
Boost Current: 12 A.
Worldwide 3-phase Power Supply.
Resistant in tough environments.
Easy and fast installation.
The most compact class on the market.
380 to 480 VAC (320 to 576 VAC).
380 to 480 VAC (340 to 576 VAC).
When using the 960 W at 2-phase input, the power rating is 768 W.
450 to 600 VDC (450 to 810 VDC).
Excluding 960 W.
High efficiency 91% typ. at 480 W model.
Wide operation temperature range: –40 to 70°C.
Power Boost function at 120%.
Meets LR maritime standards.
EMS: Conforms to EN 61204-3.
EMI: EN61204-3 Class B.
RoHS Compliant.
Rated voltage: 200 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.080 A; 60 Hz, 0.070 A .
Rated input: 50 Hz, 11 W ; 60 Hz, 10 W .
Rated rotational speed: 50 Hz, 2100 r/min; 60 Hz, 2250 r/min.
Maximum flow rate: 50 Hz, 2.0 m3/min; 60 Hz, 2 OMRON S8VK-T24024. 1 m3/min.
Maximum static pressure: 50 Hz, 44.1 Pa; 60 Hz, 44.1 Pa.
Noise: 50 Hz, 36 dB; 60 Hz, 38 dB
S8VK-T24024
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series OMRON S8VK-T24024.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Type: Medium-sensitivity models.
Sensed current: 200 mA/500 mA(switchable) OMRON S8VK-T24024.
Type: Delayed models.
Operating time: 0.3/0.8 s (switchable).
Economical, Compact, High-performance,
DIN 48 × 48-mm Ground Fault Relay for Low,
Voltages.
Performs continuous monitoring and detection of ground faults,
in low-voltage circuits due to the deterioration of insulation in,
electrical devices.
Higher reliability ensured with improved resistance to high-fre,
quency noise when used for inverter loads.
Ground Fault Relays and through-type ZCTs (zero-phase current,
transformers) are mutually compatible.
The through-type ZCTs are equipped with test terminals,
allowing operation tests for Ground Fault Relays to be performed withease. Connection method: S8 snap-in.
Panel mounting: Front lock or rear lock.
Pin shape: DIP pins.
Applicable wires: --.
Minimum ordeer: 50 S8VK-T24024.
Small Round Water-resistive.
Connectors.
Water-resistive, compact connector meets IP67 requirements.
Conventional M8 screw-mounting models are available along with,
S8 snap-in models that connect and disconnect with one toucch S8VK-T24024.
Ideal for a wide variety of FA and OA applications.
Connectors on both cable ends require no harness work.
Some new M8 models with 3 or 5 poles.