Power ratings: 120 W.
Input voltage: Single phase, 100 to 240 VAC, 90 to 350 VDC.
Output Voltage: 24 V.
Output current *1: 5 A.
Cost-effective Single Phase Power Supply.
Universal input and Safety standards.
for worldwide applications.
Space-saving Compact Design.
100 to 240 VAC (85 to 264 VAC).
DC input can be available: 90 to 350 VDC.
Operation temperature range: –25 to 60 °C.
Compact Dimension for small space.
Flexible installation by special mounting brackets.
UL508/60950-1, CSA C22.2 No.107.1/60950-1.
EN50178, EN60950-1.
EMS: Conform to EN61204-3.
EMI: EN55011 Class A.
Three years Warranty.
Rated voltage: 115 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.160 A; 60 Hz, 0.130 A .
Rated input: 50 Hz, 14 W ; 60 Hz, 12 W .
Rated rotational speed: 50 Hz, 2400 r/min; 60 Hz, 2800 r/min.
Maximum flow rate: 50 Hz, 1.9 m3/min; 60 Hz, 2 OMRON S8VK-C12024. 2 m3/min.
Maximum static pressure: 50 Hz, 44.1 Pa; 60 Hz, 42.2 Pa.
Noise: 50 Hz, 39 dB; 60 Hz, 43 dB
S8VK-C12024
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series OMRON S8VK-C12024.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control OMRON S8VK-C12024.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF contrrol, phase control, and cyclic control S8VK-C12024.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads S8VK-C12024.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).