Rated voltage: 230 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.100 A; 60 Hz, 0.085 A .
Rated input: 50 Hz, 16 W; 60 Hz, 14 W.
Rated rotational speed: 50 Hz, 2350 r/min; 60 Hz, 2750 r/min.
Maximum flow rate: 50 Hz, 1.7 m3/min; 60 Hz, 2.0 m3/min.
Maximum static pressure: 50 Hz, 36.7 Pa; 60 Hz, 37.3 Pa.
Noise: 50 Hz, 36 dB; 60 Hz, 40 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
environment.
Shaft supported by ball bearings for highly-reliable operation.
(28 type) included in series.
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
product. Check the information given for available models of Axial fans and,
the information in Characteristics.
No. of cable cores: 4.
Cable connection direction: Right-angle.
Cable length L: 0.3 m.
Small Round Water-resistive.
Connectors.
Water-resistive, compact connector meets IP67 requirements.
Conventional M8 screw-mounting models are available along with,
S8 snap-in models that connect and disconnect with one touch OMRON R87T-A6A15MP.
Ideal for a wide variety of FA and OA applications.
Connectors on both cable ends require no harness work
R87T-A6A15MP
Some new M8 models with 3 or 5 poles. Power rating: 350 W.
Input voltage: 100 to 120 VAC, 200 to 240 VAC (allowable range: 90 to 132 VAC,
180 to 264 VAC, or 254 to 373 VDC(Select with the switch.)*2).
Output voltage: 36 V VDC.
Output current: 9.7 A.
Built-in fan: Yes OMRON R87T-A6A15MP.
Model with terminal block facing upward.
High Reliability at a Reasonable Cost.
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation.
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage.
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life OMRON R87T-A6A15MP. A reliable 3-year warranty.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications.
Global Standards: Conforms to CE (all models),
Approved for UL (all models) and CCC (15 to 150-W models).
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W. Function: Phase sequence and phase loss monitoring.
Rated input voltage: 3-phase, 3-wire 200 to 480 VAC.
Relay output: SPDT × 1.
Three-phase Phase-sequence Phase-losss R87T-A6A15MP.
Relay Using Voltage Detection Method.
Lineup includes a 17.5-mm slim, compact model.
Greater resistance to inverter noise.
Distinguishes between correct phases, phase sequence, and phase,
loss when power is turned ON.
Supportss phase loss detection when the motor is operating R87T-A6A15MP.
Output status can be monitored using LED indicator.
Ideal to prevent reverse operation of motors.