Rated voltage: 115 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.120 A; 60 Hz, 0.100 A .
Rated input: 50 Hz, 10 W ; 60 Hz, 9 W .
Rated rotational speed: 50 Hz, 2700 r/min; 60 Hz, 3200 r/min.
Maximum flow rate: 50 Hz, 0.8 m3/min; 60 Hz, 0.9 m3/min.
Maximum static pressure: 50 Hz, 42.1 Pa; 60 Hz, 58.8 Pa.
Noise: 50 Hz, 32 dB; 60 Hz, 36 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
environment.
Shaft supported by ball bearings for highly-reliable operation.
(28 type) included in series.
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
product. Check the information given for available models of Axial fans and,
the information in Characteristics.
Power rating: 25 W.
Input voltage: 100 to 240 VAC (allowable range: 85 to 264 VAC or 120 to 370 VDC*1).
Output voltage: 24 V VDC.
Output current: 1.1 A.
Built-in fan: None.
Model with terminal block facing forward.
High Reliability at a Reasonable Cost.
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation OMRON R87F-A3A85HP.
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage
R87F-A3A85HP
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life. A reliable 3-year warranty.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications OMRON R87F-A3A85HP.
Global Standards: Conforms to CE (all models),
Approved for UL (all models) and CCC (15 to 150-W models).
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W. Applicable model (typical example): G2R-2-S.
New Screwless Terminal Sockets Added.
for MY and G2R Relays OMRON R87F-A3A85HP.
Simplified wiring without tightening screws.
Two wires can be independently wired for each terminal.
Coil terminals and contact terminals are completely separated,
in an organized wiring layout.
Release Levers and Nameplates are available (sold separately). No. of poles: 4.
Suitable cable dia: 8 mm dia. model (7 to 8 mm dia.).
Suitable core size: 0.18 to 0.75mm.
Suitable Sheath material: PVC, PE, PUR.
Straight connectors (for DC).
Minimum order: 50.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements aand ensure a,
94V-0 fire retardant rating R87F-A3A85HP.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of CConnector Assembly: Crimping, soldering, and screw-on R87F-A3A85HP.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202.