R87F-A_A16H-WR waterproof type AC axial flow fan (T40 * _120, wire type).
Rated voltage: 115V.
Allowable voltage range: 85 to 110% of rated voltage.
Frequency: 50/60Hz.
Rated current: 60Hz--0.175A; 50Hz--0.194A.
Rated input: 50Hz--16W:60Hz--15W.
Rated speed: 50Hz--2690r/min; 60Hz--3040r/min.
Maximum air volume: 60Hz--2.5m3/min; 50Hz--2.3m3/min.
Maximum static pressure: 50Hz--70.9Pa; 60Hz--69.6Pa.
Noise: 50Hz--43dB; 60Hz--46dB.
The axial flow fan with the best cooling is realized.
The design of low noise, high life and good environmental adaptability is considered.
Bearing with high reliability.
Specification for type 48 and metal blade with resin blade 24.
(protection structure IP65).
Through UL, CSA, VDE safety standards, EN/IEC certification of the aircraft is also very rich.
Type: Cable with Connectors on Both Ends (RJ45/RJ45).
Category: Cat.5 .
Cable sheath material: PUR.
Cable color: Green.
Cable length: 2 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Cable length L: 2.0 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch OMRON R87F-A3A16H-WR. Time specification: Instantaneous type
R87F-A3A16H-WR
Current setting range: 20 to 65 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase OMRON R87F-A3A16H-WR.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions OMRON R87F-A3A16H-WR. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Ideal for Voltage Monitoring for.
Industrial Facilities and Equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and undervoltages.
Manual resetting and automatically resetting supported by one Relay.
Pre-alarm Monitoring Mode.
Two SPDT output relays, 5 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Type: S8JC-Z series models list.
Meet the criteria: No.
Configuration: power supply with coover; bottom surface mounting R87F-A3A16H-WR.
Input voltage: 100W.
Output voltage: 24VDC.
Output current: 4.5A.
Economic type power supply S8JC-Z additional models,
The new power S8JC-ZS has a CE certification mark to market.
Product features: reducce material costs;
Export machinery to be used to meet specific safety standards;
Through the DIN guide rail installation, significant savings in time R87F-A3A16H-WR.