OMRON
Home >> Products >> OMRON >> Relay >> General relay >> Relay for control cabinet >> LY2N-J | OMRON General purpose relay LY2N-J

LY2N-J | OMRON General purpose relay LY2N-J


OMRON LY2N-J Product information and technical parameters:
Brand: OMRON
Name: General purpose relay
Model: LY2N-J
Construction: insert / solder terminal.
Contact form: DPDT.
Indicator: led.
Note: when the order is ordered, the number of the models is added with the rated voltage of the coil.
For example: DC12 DC12, LY1-J on behalf of the rated voltage of the coil.
Arc barrier equipped with high insulation strength (AC2000V).

Standard certification: No.
Insulation mode: three end two-way photoelectric switch.
Zero trigger function: No.
Action indicator: No.
Applicable load of output: AC100 3A ~ 240V.
Input rated voltage: DC12V.
With the LY1, LY2 large power relay with the same shape of the G3H series, the new international standard certification (-VD type) OMRON LY2N-J.
Achieved UL, CSA, EN (VDE certification) standard certification LY2N-J (type -VD)
Socket terminal type of same size with LY (1 pole, 2 pole type).
A model with an action indicator to check the status of the input. (type N)Action indicator: built-in type of mechanical indicator.
Number of contacts: 4 pole.
Operating coil voltage: DC24V.
Universal relay the best-selling MY standard mechanical indicator, can confirm the action state contact OMRON LY2N-J.
According to the LED action indicator light color, can identify the AC coil specifications, DC coil specifications.
Online lap tape printing operation coil specifications, the recognition is higher.
All standard specifications indicating mechanism of mechanical action (mechanical indicator).
Suitable for environmental protection RoHS OMRON LY2N-J.
Conforms to the UL, CSA, IEC (VDE) standardIsolation: Photo-voltage coupler.
Zero cross function: No.
Indicator: Yes.
Rated output load: 0.5 A at 24 to 240 VAC, 0.5 A at 24 to 110 VDC.
Rated input voltage: 24 VDC.
100-A-max. Leakage Current, No Bleeder.
Resistor Required.
1 mA to 500 mA micro-load switching.
Switch to both AC and DC with no polarity.
Switch for a wide range of voltages; 19.2 to 264 VAC, 19.2 to 125 VDC.
Switch full- and half-wave rectifier AC loads.
Same sizes and terminal arrangements as OMRON Power,
Relay MY Series.
Operating indicator provided.
Switch MY Series (without bleeder resistor).
Superior surge absorption with a built-in varistor.
Optimum SSR to control minute load, valves, and solenoids. Ontology: UL standard certification type and insert terminal type.Number of phases: Single-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Applicable load: 35 A, 100 to 240 VAC.

Compact, Slim-profile SSRs with Heat,
Sinks LY2N-J. Models with No Zero Cross for,
a Wide Range of Applications.
RoHS compliant.
Models also available with no zero cross,
Surge pass protection improved surge dielectric strength for,
output cuurrents LY2N-J. (OMRON testing).
Compact with a slim profile.
Mount to DIN Track or with screws.
Conforms to UL, CSA, and EN standards (TÜV certification).


...More relevant models >>>>