Models: OVR (59).
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side / internal tributaries.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determine the direction of the sudden drop in the voltage to 0 of the short-circuit accident.
Visual inspection by the standard to improve reliability.Cable Specifications: Standard cable (non-polar).
Cable connection direction: L-shaped.
Cable diameter: 6.0 mm dia.
No. of cable cores: 2.
Cable core cross sectional area: 0.5 mm.
Cable length: 2 m.
AC.
Minimum order: 5.
UL-listed: -- OMRON K2ZC-K2VA-N.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort
K2ZC-K2VA-N
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on OMRON K2ZC-K2VA-N.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Control power supply voltage: 100/110 VAC.
Input: DC or AC (selectable), Input voltage range, 0.2 to 12 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL) OMRON K2ZC-K2VA-N.
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@). No. of poles: 4.
Connection method: Soldering.
Suitable cable dia: 4 mm (4 to 5).
Core conductor size: 0.5 max.
Suitable sheath material: PVC, PE, PUR.
Angled Connectors.
Minimum order: 50.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work K2ZC-K2VA-N.
A newly developed lock mechanism that is compatible with round M12 connectors.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock.
A positive click indicates loccking K2ZC-K2VA-N.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved.