OMRON
Home >> Products >> OMRON >> Power/other peripheral devices >> Power / equipment protection equipment >> Protective equipment for equipment >> K2CU-F20A-C | OMRON Heater Element Burnout Detector K2CU-F20A-C

K2CU-F20A-C | OMRON Heater Element Burnout Detector K2CU-F20A-C

OMRON K2CU-F20A-C Manual And Instructions
K2CU-F20A-C datasheetPDF datasheet

OMRON K2CU-F20A-C Product information and technical parameters:
Brand: OMRON
Name: Heater Element Burnout Detector
Model: K2CU-F20A-C
Control supply voltage: 100 VAC; With voltage fluctuation compensation.
Operating current: 8 to 20 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage.

Power ratings: 480 W.
Input voltage: 100 to 240 VAC.
Output voltage: 24 V.
Output current: 20 A Peak current 30 A (200 VAC).
Alarm output *2: Sinking/sourcing.
UL Class 2 Output standards: --.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication OMRON K2CU-F20A-C.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that K2CU-F20A-C
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC OMRON K2CU-F20A-C.
(Not compliant with EC Directives and other safety standards.) Cable type: Standard Cables.
Type: Cable with Plugs on Both Ends (M12 Straight/M12 Straight).
Cable length: 2 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Power ratings: 240 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1 OMRON K2CU-F20A-C.
Output voltage: 24 V.
Output current: 10 A.
Alarm output *2: Sourcing.
UL Class 2 Output standards: --.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Type: Ultra cooling head.
Cable length: 0.3 m.
Cost Revolution Led by UV Curing.
System.
Minimal heat damage thanks to UUV-LED irradiation K2CU-F20A-C.
New UV LEDs with much higher brightness mounted in heads.
Greater irradiation power to reduce bonding tact time.
Usage of LEDs that have a long lifetime of 40,000,
hours* drastically reduces running costs.
Ultra compact body that is approximately 1/8th the size,
of a conventional lamp system K2CU-F20A-C.
Equipped with a color LCD that makes settings simple and reliable.


...More relevant models >>>>