Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
rent, open-phase, and reverse-phase.
ing the test button.
is indicated from the start of operation.
Space-saving, integrated construction.
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Function: Temperature monitoring.
Power supply voltage: 100 to 240 VAC.
Monitor Temperature Rise through.
Internal Motor Loss.
Temperature, phase sequence, and phase loss monitoring with,
the DIN 22.5-mm-sized K8AK-PT Relays.
Side-by-side mounting of K8AK-PT Relays.
Specially designed for internal motor monitoring; no setting required OMRON K2CM-4LA.
Test/Reset Button for confirmation of output operation
K2CM-4LA
Monitoring also performed for thermistor disconnections and short circuits.
Manual or automatic resetting with the same Relay. Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V).
Easy Mounting: Front-mounted type, DIN rail-mounted type are available.
Screw-mount at the top OMRON K2CM-4LA. (except 300-/600-W models).
Safety standards: UL 508/60950-1, cUL CSA C22.2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA).
Input conditions: The input voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply OMRON K2CM-4LA. ).Servo trunk unit.
Product Name: servo relay unit.
Application unit: CJ1M-CPU21/22/23.
Specifications: -.
Axis number: biaxial.
The connector and terminal of the relay unit are integrated into a whole,
Save the wiring servo drive and position control unit.
Servo driver and control signal of position control unit,
Simple wiring on terminal stage.
The connector without soldering, with only a screwdriver can wiring.
Dedicated connection cable between units.
DIN guide rail installation, the rapid installation, screw installation of two methods.
M3.0 thread terminals attached with a special plate signal.
The terminal can be confirmed by the signal name.
Cable type: Standard Cables.
Type: Cable with Plugs on Both Ends (RJ45/RJ45).
Cable length: 3 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF coontrol, phase control, and cyclic control K2CM-4LA.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K2CM-4LA.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).