OMRON
Home >> Products >> OMRON >> Power/other peripheral devices >> Power / equipment protection equipment >> Protective equipment for equipment >> K2CM-2LV | OMRON Motor Protective Relay K2CM-2LV

K2CM-2LV | OMRON Motor Protective Relay K2CM-2LV

OMRON K2CM-2LV Manual And Instructions
K2CM-2LV datasheetPDF datasheet
K2CM-2LV Communications Manual

OMRON K2CM-2LV Product information and technical parameters:
Brand: OMRON
Name: Motor Protective Relay
Model: K2CM-2LV
Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,

Power rating: 350 W.
Input voltage: 100 to 120 VAC, 200 to 240 VAC (allowable range: 90 to 132 VAC,
180 to 264 VAC, or 254 to 373 VDC(Select with the switch.)*2).
Output voltage: 12 V VDC.
Output current: 29 A.
Built-in fan: Yes.
Model with terminal block facing upward.
High Reliability at a Reasonable Cost OMRON K2CM-2LV.
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation K2CM-2LV
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage.
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life. A reliable 3-year warranty.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications OMRON K2CM-2LV.
Global Standards: Conforms to CE (all models),
Approved for UL (all models) and CCC (15 to 150-W models).
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W. Rated voltage: 115 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage OMRON K2CM-2LV.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2300 r/min; 60 Hz, 2600 r/min.
Maximum flow rate: 50 Hz, 0.8 m3/min; 60 Hz, 1.0 m3/min.
Maximum static pressure: 50 Hz, 41 Pa; 60 Hz, 45 Pa.
Noise: 50 Hz, 41 dB; 60 Hz, 44 dB.
Weight: Approx. 1150 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting.
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and Vent Attachment.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades. Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
iis indicated from the start of operation K2CM-2LV.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K2CM-2LV. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.


...More relevant models >>>>