I/O classification: Counter Unit.
External I/O points: Inputs: 1, Outputs: 2.
I/O connections: Terminal block.
Operating mode: Linear counter.
Input for Use with MULTIPLE I/O TERMINAL.
High-speed pulse with counting speed of 50 kHz.
Counting can be set to a multiplication factor of 1 or 4.
Wide range of measurement: -8,388,608 to 8,388,607.
One external input and two external outputs are available.
DIN track mounting.
Name: Three-tier Screw Terminal Block.
Specifications: Inputs; 16 inputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system OMRON GT1-CT01.
A wide variety of CompoNet Slave Units,
contribute to system size reduction
GT1-CT01
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Independent type, the function of the built-in controller is not RS-232C, the maximum 256 points OMRON GT1-CT01. Specifications: I/O;
NPN (input: + common, output: - common);
Input: 8 points/Output: 8 points.
I/O connections: M3 Screw terminals.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Allows I/O Expansion with Transistor Terminals.
Wide variety of data, such as maintenance system data,
can be collected without affecting the productivity,
of the control system OMRON GT1-CT01.
Valuable information can be collected,
and managed through the network, including information,
on the communications power supply.
voltage levels, Unit wear and tear,
and equipment operating information.
Expansion via Expansion I/O Units.
With no communications baud rate settings,
required and detachable terminal blocks,
maintenance is easier. Name: MIL Connectors.
Specifications: Outputs; 32 outputs ; NPN; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring materrial cost can be reduced GT1-CT01.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee GT1-CT01.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.