Name: Slice I/O Units; Temperature Input.
(Resistance Thermometers).
(Resistance thermometer:Pt100) 2 points.
Standards: CE, UC1, L.
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
wiring in the system.
contribute to system size reduction.
helps to detect errors on site.
content of the error.
Name: e-CON Connectors.
Specifications: Outputs; 8 outputs ; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system OMRON GRT1-TS2P.
A wide variety of CompoNet Slave Units,
contribute to system size reduction
GRT1-TS2P
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Unit: Connector model.
I/O classification: Digital input OMRON GRT1-TS2P.
Internal I/O common: NPN (+ common).
I/O points: 16.
I/O connections: D-sub 25-pin connector.
Power supplyvoltage: 24 VDC.
I/O specification: DC/transistor.
Digital I/O Units Compatible with MULTIPLE I/O TERMINAL,
Terminal block, connector, and high-density connector,
models are available.
The circuit block of the terminal block model can be,
mounted or dismounted for ease of maintenance without,
disconnecting the wires OMRON GRT1-TS2P.
DIN track mounting. Short/disconnection detection: Supported.
Specifications: Inputs, NPN (+ common), 16 points.
I/O connections: Clamp terminals.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
Reduced Wiring and Labor on Factory Sites with Screw-less Terminal Wiring.
Screw-less structure eliminates tightening work.
Detachable terminal blocks for easier maintenance.
Single-step wiring by simply inserting pole terminals. Input type: Thermocouple input.
I/O points: 4 inputs allocated 4 input words at the Master Unit,
(8 input words allocated when 1/100 display mode is selected).
Temperature Input Terminal with Smart Functionality.
The Temperature Input Terminal can be used with almost the same functionality as a GRT1-TS2P.
Analog Input Terminal, such as with scaling and comparator functions.
Enhanced performance is provided with functionality specific to the Temperature,
Input Terminal, such as the recording the operating time in a preset temperature,
range and temperature difference detection between input channels GRT1-TS2P.