Low-speed Monitoring Function Ensures.
Safety for Maintenance Work.
Motor rotation speed detected by Proximity Sensor.
Monitors and confirms that speed does not exceed the preset level.
Includes an Enabling Switch input for maintenance work.
Detailed LED indications enable easy fault diagnosis.
SIL 3 (IEC/EN 62061) certified.
Main contacts: 3PST-NO.
Auxiliary contact: SPST-NC.
OFF-delay time: 7.5 S.
The G9SA Series Offers a Complete.
Line-up of Compact Units.
Four kinds of 45-mm wide Units are available:
A 3-pole model, a 5-pole model, and models with 3 poles,
and 2 OFF-delay poles, as well as a Two-hand Controller OMRON G9SX-LM Series.
Also available are 17.5-mm wide Expansion Units with 3,
poles and 3 OFF-delay poles
G9SX-LM Series
Simple expansion connection.
OFF-delay models have 15-step OFF-delay settings.
Conforms to EN ISO13849-1 (PLe/Safety Category 4).
Both DIN track mounting and screw mounting are possible. Actuator: Roller plunger.
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 2NC (Slow-action).
Popular Safety Limit Switches OMRON G9SX-LM Series.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads OMRON G9SX-LM Series.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Number of beams: 70.
Protective height: 1400mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions. Lock method: Solenoid lock.
Conduit size: M20.
Voltage for solenoid: 24 VDC.
Without indicator 2NC+ 1NC (Slow-action).
Release Protective Cover Locks Using.
Controller Signals or Pushbutton.
Switches after the Cutting Tool Stops.
Moving Due to Inertia.
A mechanical lock is applied automatically when the Operation.
Key is inserted. A high level of safety is achieved using a,
mechanism where the lock is only released when voltage is,
applied to the solenoid.
Conforms to EN (TÜV) standards corresponding to the CE marking.
Certified by UL, CSA and CCC standards.
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened.
Direct opening mechanism that is EN-certified is indicated by,
on the Switch.
Auxiliary release key ensures easy maintenance and unlocks the,
door in the case of a power failure.
Tough aluminum die-cast body incorporating a switch box wwith,
degree of protection satisfying IP67, UL, and CSA TYPE6P, 13 G9SX-LM Series.
Equipped with a horizontal and vertical conduit opening.
Models incorporating easy-to-see indicators for monitoring and,
those using an adjustable Operation Key ffor a swinging door are available G9SX-LM Series.
The mounting direction of the head can be changed,
to allow the Operation Key to be inserted from four directions.