Isolation method: Relay.
Zero cross function: No.
Operation indicator: Yes.
Applicable output load(See note.): 10 A 100 to 240 VAC.
Rated input voltage: 5 VDC.
Operations.
UL/CSA certified (-VD models).
million operations.
radiators. Plus, there is almost no effect on heat generation,
or ambient temperature.
Operation indicators to easily check operation.
triac or relay malfunctions.
LY Relays.
Construction: insert / solder terminal.
Contact form: SPDT.
Indicator: no light.
Note: when the order is ordered, the number of the models is added with the rated voltage of the coil.
For example: DC12 DC12, LY1-J on behalf of the rated voltage of the coil.
Arc barrier equipped with high insulation strength (AC2000V) OMRON G9H-210S-US DC5. Type: Standard.
Contact form: 3PDT.
Open structure: Solder terminals
G9H-210S-US DC5
Mechanically Latching Relays Based on the.
MM Power Relay.
Low power consumption due to mechanical latch for economic operation.
Relays with mixed coil specifications can be produced,
(e.g., AC setcoil and DC reset coil).
Operational response fast enough to enable pulse signal power applications OMRON G9H-210S-US DC5.
Ambient operating temperature: –10°C to 55°C. Structure: Relays with PCB Terminals.
Classification: Standard models Compliance with Electrical,
Appliances and Material Safety Act.
Number of poles: 1.
Power-switching Compact.
General-purpose Relays.
The standard models include models that are,
compliant with the UL, CSA, and SEV safety.
standards and with the Electrical Appliances and,
Material Safety Act OMRON G9H-210S-US DC5.
Equipped with an arc barrier for arc interruption.
Withstand voltages up to 2,000 V.
New built-in diode and built-in CR circuit models have,
joined the series.
The lineup also includes models that are compliant,
with the LR and VDE safety standards.
Single-pole and double-pole models have AC4,
ratings and DC2 ratings (operating coil ratings:
100/110 VAC, 110/120 VAC, 200/220 VAC, 220/240 VAC,
and 100/110 VDC).
Three-pole and four-pole models have AC4 ratings,
and DC2 ratings (operating coil ratings: 100/110,
VAC, 200/220 VAC and 100/110 VDC). Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes.
Rated output load: 2 A at 100 too 240 VAC (See note 1 G9H-210S-US DC5. ).
Rated input voltage: 200/220 VAC.
International Standards for G3F Series,
Same Profile as MY Power Relays.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (model numbers with a sufffix of“-VD”) G9H-210S-US DC5.
Socket type, same size as MY Power Relays.
Operation indicator provided to confirm input.
(model numbers with “N” before the suffix).