Cable /G79-Y_C with loose wire connecting terminal.
L size: 5000mm.
Connector cable, MITSUBISHI motor produced PLC connection cable.
Input voltage: 24 to 28 VDC.
Output voltage: 24 V.
Output current: 3.7 A/8 A (See note 2.).
DC Backup Block for S8TS Prevents 24-VDC.
Outages Due to Power Interruptions or Failures.
Supplies 24 VDC for a fixed period of time even during.
AC input outages to considerably improve system reliability OMRON G79-Y500C.
Block Power Supply Basic Block is connected using a Bus Line.
Connector to achieve a simple system configuration
G79-Y500C
Notification of alarms is provided by indications on the main unit.
and alarm signal output.
RoHS-Compliant. Power rating: 75 W.
Input voltage: 100 to 240 VAC (allowable range: 85 to 264 VAC or 120 to 370 VDC*1).
Output voltage: 12 V VDC.
Output current: 6.2 A.
Built-in fan: None OMRON G79-Y500C.
Model with terminal block facing forward.
High Reliability at a Reasonable Cost.
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation.
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage.
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life OMRON G79-Y500C. A reliable 3-year warranty.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications.
Global Standards: Conforms to CE (all models),
Approved for UL (all models) and CCC (15 to 150-W models).
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W. Easy-to-use DIN Rail Mounting Bracket for,
Power Supplies.
Mounts to the PFP-100N and PFP-100N2 DIN Rails.
Supports models S82J (100, 150-W models). Control power supply voltage: 24 VDC.
Input: DC, Input voltage range, 0.2 to 12 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current convertter G79-Y500C.
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verrse current detection G79-Y500C.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).