Equipped with built-in G6D relay type and non contact G3DZ power FET MOS relay type, complete varieties.
Disassembly tool with relay.
Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: DIN track mounting *2.
Applicable load: 15 A, 100 to 240 VAC.
Number of pole: 3.
Compact, Slim-profile SSRs with Heat Sinks OMRON G6D-4B Series/G3DZ-4B Series.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work
G6D-4B Series/G3DZ-4B Series
with DIN Track Mounting.
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIN Track mounting types mount to DIN Track.
(applicable DIN Track: TR35-15Fe (IEC 60715)) OMRON G6D-4B Series/G3DZ-4B Series.
Conforms to UL, CSA, and EN standards (TÜV certification). Input terminals: Compact slotted screw terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note.): 2 to 25 A, 200 to 480 VAC OMRON G6D-4B Series/G3DZ-4B Series.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp terminals (detachable), or compact slotted,
screw terminals (detachable).
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified. Refer to Safety Precautions for All Solid State Relays.
Prevents G3PA Malfunction.
Connects to a maximum of two G3PA-VD Relays.
Prevents malfunction of the G3PA-VD due to residual voltage,
leakage current, or input noise. Isolation method: Relay.
Zero cross function: No.
Operation indicator: Yes.
Applicable output load(See note.): 5 A 100 to 240 VAC.
Rated input voltage: 5 VDC.
Hybridization of a Magnetic Relay and an,
SSR Achieves 10-A Switching for 10 Million,
Operations.
UL/CSA certified (-VD models).
Using a triac to open and close the circuit reduces chattering,
and arching, thereby increasing the electrical durability to 10,
million operations.
Relays contacts for power ON and 10-A switching withh high,
capacity are provided in a compact body without the need of,
radiators G6D-4B Series/G3DZ-4B Series. Plus, there is almost no effect on heat generation,
or ambient temperature.
Operation indicators to easily check operation.
Built-in teemperature fuse prevents internal burning due to,
triac or relay malfunctions G6D-4B Series/G3DZ-4B Series.
Socket-type Relays the same size as the 1-pole and 2-pole,