With the same shape of the power FET MOS G2R relay AC/DC dual, can achieve 1A load switching performance.
Can be carried out AC full wave rectifier load, half wave rectifier load switch.
Category: built-in diode (DC).
Contact form: 4DPDT.
Structure: insert / solder terminal.
Indicator: with LED indicator light.
Note: when the order is ordered, the number of the models is added with the rated voltage of the coil.
For example: AC6V AC6V, MY2-J on behalf of the rated voltage of the coil OMRON G3RZ-201SLN DC12.
Upgraded version of the small power relay, there are a variety of models, suitable for a variety of sequential control and power applications
G3RZ-201SLN DC12 Contact form: SPST-NO.
Type: Standard Models.
Rated voltage: AC: 24, 100, 110, 120, 200, 220, 230, 240;
DC: 12, 24, 48, 110, 220.
MK-S-series Relays with DC-switching,
Models That Can Switch 220 VDC, 10 A,
(Resistive Load).
Switch a DC load of 220 VDC, 10 A (resistive load) OMRON G3RZ-201SLN DC12.
Models for AC Loads can switch 250 VAC, 15 A (resistive load).
Lineup includes models with SPST-NO and SPST-NO/SPST,
NC contact forms.
Using a SPST-NO/SPST-NC contact form enables detecting,
contact welding. (When the NO contacts become welded, the,
NC contacts will maintain a minimum distance of 0.5 mm.).
Models available with operation indicators and built-in test buttons OMRON G3RZ-201SLN DC12.
RoHS compliant.
Standards: UL, IEC (TÜV certification). Construction: insert / solder terminal.
Contact form: 4PDT.
Indicator: no light.
Note: when the order is ordered, the number of the models is added with the rated voltage of the coil.
For example: DC12 DC12, LY1-J on behalf of the rated voltage of the coil.
Arc barrier equipped with high insulation strength (AC2000V). Classification: Relay with Auxiliary Contact Block.
Structure: 4 poles + 2 poles.
Contact configuration: Relay, DPST-NO/DPST-NC; Auxiliary Contact Block, DPST-NC.
Rated Voltage: 12, 24 VDC.
Compact Electromagnetic Contactors That.
Switch 40 A at 440 VAC.
One pole carries 40 A.
UL 508 and UL 840 NC contacts (resistive 40 A 480 VAC, 60 Hz, 80,000 operations).
EN 60947-4-1 NC contacts (AC1 40 A 440 VAC, 50/60 Hz, 80,000 operations).
Ideal for supply power to industrial inverters, servo drivers, and other devices,
and switching power to motors and other equipment.
The maximum load capacity of 160 A when using 4-pole parallel connections.
EN 60947-4-1 certification for mirror contact mechanism obtained by combbining,
the Relay with an Auxiliary Contact Block G3RZ-201SLN DC12.
Conforms to European PV standard (VDE0126).
Approx. 30% less operation noise than a standard electromagnetic contactor.
(Approx. 100 dB reduced to approx. 70 dB.)
Approx. 50% thhe volume of a standard electromagnetic contactor,
to help downsize control panels G3RZ-201SLN DC12.
According to OMRON investigation of IIEC-AC1 50 A specifications.