OMRON G3RV-SR500-A AC100 Product information and technical parameters:
Brand: OMRON
Name: Slim I/O Relay
Model: G3RV-SR500-A AC100
Terminal (wire connection): Push-In Plus Terminal.
Applicable output load: AC load.
Zero cross function: Yes.
Rated input voltage: AC 100V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals.
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange.

Input terminals: Compact slotted screw terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note.): 2 to 25 A, 200 to 480 VAC OMRON G3RV-SR500-A AC100.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short G3RV-SR500-A AC100
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws OMRON G3RV-SR500-A AC100.
Three types of input terminals available: M3 terminals,
screwless clamp terminals (detachable), or compact slotted,
screw terminals (detachable).
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified. Terminal (wire connection): Screw terminal.
Applicable output load: DC load.
Zero cross function: --.
Rated input voltage: DC 24V.
Global standard size,
low profile slim I/O relay with width 6 OMRON G3RV-SR500-A AC100. 2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals.
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for strandedd wires G3RV-SR500-A AC100.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. Name: AC Input Unit.
Rated input voltage: 1000/120 VAC G3RV-SR500-A AC100.
Refer to Safety Precautions for All Solid State Relays.
AC Input Unit Enabling AC Operation.
Connects to a maximum of two G3PA-VD Relays.