Isolation: Phototriac coupler.
Zero cross function: Yes.
Indicator: Yes.
Rated output load: 40 A at 24 to 240 VAC.
Rated input voltage: 5 to 24 VDC.
Extremely Thin Relays Integrated with Heat Sinks.
Downsizing achieved through optimum design of heat sink.
Mounting possible via screws or via DIN track.
Close mounting possible for linking terminals.
Applicable with 3-phase loads.
Replaceable power element cartridges.
with a dielectric strength of 4,000 V between input and load.
Certified by UL, CSA, and VDE (reinforced insulation).
Name: Multi-channel Power Controller.
Number of control channels: 4.
Heater burnout detection: Not supported.
Load power supply voltage: 400 to 480 VAC.
Optimum Cycle Control for High-precision.
Control with Low Noise.
Smaller than a Normal Power Controller.
Enables low-noise power control in combination with zero-cross OMRON G3PA-240B-VD DC5-24.
SSRs. (See note.).
One Controller can control up to 8 SSRs
G3PA-240B-VD DC5-24
RS-485 communications to set manipulated variables and,
heater burnout detection. The Smart FB Library for the G3ZA,
can also be used.
CE Marking.
Main Upgraded Functions.
Soft-start function added for lamp heaters.
Three-phase optimum cycle control added for three-phase heaters.
Combining with special CT for150-A current detection OMRON G3PA-240B-VD DC5-24.
Note: The G3ZA must be used in combination with an SSR without the,
zero cross function when the soft-start function is used. A High-capacity, High-dielectric-strength,
Multi-pole Relay Used Like a Contactor.
Miniature hinge for maximum switching power for motor loads,
as well as resistive and inductive loads.
No contact chattering for momentary voltage drops up to 50%,
of rated voltage OMRON G3PA-240B-VD DC5-24.
Withstanding more than 4 kV between contacts that are differ,
ent in polarity and between the coil and contacts.
Flame-resistant materials (UL94V-0-qualifying) used for all in,
sulation material.
Standard models approved by UL and CSA. Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: NO.
Rated output load: 3 A at 100 to 240 VAC (See note 1.).
Rated input voltage: 4 to 24 VDC.
International Standards for G3F Series,
Same Profile as MY Power Relays.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (model numbers with a suffix of“-VD”).
Socket type, same size as MY Power Relays.
Operation indicator provided to confirm input.
(model numbers with “N” before the suffix). The main body: with shell type / socket terminal type.
Category: action device built in.
Pole number: 2 pole.
A vvariety of eight pin pin type electric power G3PA-240B-VD DC5-24.
With shell models have AC4 rated specifications (50/60Hz AC200/220V, 50/60Hz AC100/110V).
Installation, wiring convenient, easy to operate.
Has more than 5 million mechanical life,, durable G3PA-240B-VD DC5-24.
Standard type, with shell type, special contact specifications, double contact type, double coil latch type, etc., the product is complete.