Number of elements: 2.
Insulation method: Phototriac.
Rated supply voltage: 12 to 24 VDC.
Applicable motor: 0.75 kW (4.8 A), 200 to 220 VAC.
and Achieve Harmonized Protection with Thermal.
Overload Relays.
Certified for UL and CSA.
Mount with screws or to DIN tracks.
Compact monoblock construction (W: 80 × H: 100 × D: 100 mm).
with a heat sink.
Snubber circuit and varistor are built-in.
Operation indicator.
Two-element models added to series.
The main body: with shell type / socket terminal type.
Classification: internal connection special type (contact Ag).
Pole number: 3 pole.
A variety of eight pin pin type electric power.
With shell models have AC4 rated specifications (50/60Hz AC200/220V, 50/60Hz AC100/110V).
Installation, wiring convenient, easy to operate OMRON G3J-205BL-2 DC12-24.
Has more than 5 million mechanical life, durable
G3J-205BL-2 DC12-24
Standard type, with shell type, special contact specifications, double contact type, double coil latch type, etc., the product is complete. Standard certification: No.
Action indicator: there.
Applicable load of output: AC100 2A ~ 240V.
Input rated voltage: AC100/110V.
Insulation: photo coupler.
Zero crossing trigger function OMRON G3J-205BL-2 DC12-24.
And the MY type of the same shape of the G3F series of new international standard certification (-VD type).
Achieved UL, CSA, EN (VDE certification) standard certification. (type -VD)
Socket terminal type of same size with MY (2 pole type).
A model with an action indicator to check the status of the input. Control terminal block: Screwless clamp terminal block.
Type: Standard OMRON G3J-205BL-2 DC12-24.
Capacity: 45 A, 100 to 240 VAC.
Heater burnout detection: No.
Communications: No.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control.
RS-485 communications to set manipulated variables and,
monitor load current.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,
and constant-current control.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified. Isolation: Phototriac coupler.
Zero cross function: Yes.
Indicator: Yes.
Rated output load: 60 A at 24 to 240 VAC.
Rated input voltage: 5 to 24 VDC.
Extremely Thin Relays Integrated with Heat Sinks.
Downsizing achieved through optimum design of heat siink G3J-205BL-2 DC12-24.
Mounting possible via screws or via DIN track.
Close mounting possible for linking terminals.
(Except for G3PA-260B-VD and G3PA-450B-VD-2.)
Applicable with 3-phase loads.
Replaceable power element cartridges.
Comply witth VDE 0160 (finger protection),
with a dielectric strength of 4,000 V between input and load G3J-205BL-2 DC12-24.
Certified by UL, CSA, and VDE (reinforced insulation).