Name: Basic Unit(gradient temperature control)(See note 1.).
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 2.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive)(See note 2.).
Control outputs 3 and 4: Transistor output: 2 points(sourcing).
Auxiliary output: None.
Functions: Heater burnout alarm, 2 (See note 3.); Event inputs, None.
RS-485 From End Unit, Port A, RS-485.
analog voltage, and analog current selectable for each channel.
Terminal: Screw-less clamp.
Gradient Temperature Control to Achieve.
Consistent Layer Temperature.
Perform gradient temperature control ranging from 2 to 32 channels.
groups, or 32-channel gradient temperature control for up to 2 groups.
Set gradient temperature control or 2-PID control for each group.
connections to Programmable Controllers. (The same feature,
as Standard-control EJ1 Models.).
using optimum cycle control for high-accuracy control with minimal noise.
Name: Terminal Unit(Includes bus system without backplane.).
No. of control points: 18 (See note 1.).
Functions: Not equipped with communications terminals for power supply,
communications, and setting devices.
New DIN Track Mounting Temperature.
Controller.
Two channels of temperature control available despite width of,
only 22 OMRON EJ1G-TC2B-QNH. 5 mm.
The Temperature Controller itself can be replaced without,
changing terminal wiring
EJ1G-TC2B-QNH
Use in combination with a compact Setting Display Unit to,
reduce communications programming requirements.
Front-panel LED indicators for easy operation monitoring.
Power supply and communications wiring not required between,
Units when mounted side-by-side.
CompoWay/F communications protocol supported OMRON EJ1G-TC2B-QNH.
UL, CSA, and CE Marking compliance. Size: 96 × 96 mm.
Control type: Basic control (1 loop).
Control mode: Single-loop standard control Single-loop heating and cooling control.
Outputs(control/transfer): 2 points: Current and Current.
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 6; Serial communications, RS-485.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity OMRON EJ1G-TC2B-QNH.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When using models with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4.0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation).
DeviceNet Communications.
Data setting and monitoring can be performed without special programming. Classification: Generalpurpose Models.
Description: Sheathed platinum resistance thermometer.
Temperature range (See note 3.): -196°C to 450°C.
Element type: Pt100.
Conductor type: 3-conductor system.
Class: B.
Protective tubing material: SUS316.
Terminal type: Exposed lead wires.
Page: 33.
A Wide Variety of High-precision.
Temmperature Sensors EJ1G-TC2B-QNH.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal EJ1G-TC2B-QNH.