Size: 1/8DIN 48 × 96 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Temperature Input Type.
Control method: Valve Control.
Number of alarms: 2.
Communica- tions function: RS-485.
Event input: None.
A position proportional control model for the E5EZ-PRR series.
Depth of only 78 mm.
infrared temperature sensor, voltage inputs) and analog inputs (current, voltage),
for simplicity.
and clarity.
clearly displaying the state of control (operations).
Event input enables multi-SP selection and run/ stop function.
Alarm delay function.
Communications function.
Able to choose closed/floating control. In floating control,
Equipped with a manual output function (equipped with an automatic/manual key),
CE marking and UL/CSA certification.
Size: 1/16 DIN 48 × 48 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Alarm output: 2.
option units Mounting: Yes.
Control output: Current output.
Previous mode: E5CZ-C2M.
This Best-selling General-purpose,
48×48-mm Temperature Controller,
Is Now Even Better OMRON E5EZ-PRR203T.
Controllers now available with analog inputs.
Faster sampling at 250 ms
E5EZ-PRR203T
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Easy setting with 11-segment displays.
Setting protection indicator informs operator when,
protection is enabled.
Manual output provided.
New protocol called Modbus is installed in the models,
with communications OMRON E5EZ-PRR203T.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1.6 dia.
Protective tubing length L: 15cm.
Lead wire type: Standard.
Lead wire length M : 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work OMRON E5EZ-PRR203T.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Control output 1: Relay output.
Control output 2: --.
Auxiliary output: Two.
Communications: --.
Heater burnout: --.
Event inputs: --.
Power supply voltage: 24 VAC/VDC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setupp and Operation E5EZ-PRR203T.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm E5EZ-PRR203T.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other.