The use of communication adapter cable (sold separately) connected to the computer after,
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Add position proportional control type, also support control valve control.
Classification: Low-cost Models.
Description: Low-cost platinum resistance thermometer.
Temperature range (See note 3.): -50°C to 250°C.
Element type: Pt100.
Conductor type: 3-conductor system.
Class: B.
Protective tubing material: SUS304.
Terminal type: Exposed lead wires.
Page: 17.
A Wide Variety of High-precision OMRON E5EC-TQX4DSM-068.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work
E5EC-TQX4DSM-068
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal OMRON E5EC-TQX4DSM-068. Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 4.8 dia.
Protective tubing length L: 35 cm.
Lead wire type: Heat resistive.
Lead wire length M: 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers OMRON E5EC-TQX4DSM-068.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. A New High-performance Controller: High Resolution, High Speed,
and High Input Accuracy.
Logic Operations and Preventive.
Maintenance Function.
High-resolution display with 5 digits/0.01°C display in a compact,
Controller (48 x 48 mm).
High-speed sampling cycle of 60 ms.
High Accuracy,
Thermocouple/Pt input: ±0.1% of PV,
Analog input: ±0.1% FS,
Universal inputs on all models (thermocouple, PT, or analog,
input) to handle various sensors with one Controller.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5EC-TQX4DSM-068.
Flexible contact outputs with logic operations (AND, OR, and,
delays) set froom the Support Software (CX-Thermo Ver E5EC-TQX4DSM-068. 4.0),
Preventive maintenance for relays in the Temperature.
Controller using a Control Output ON/OFF Counter.