The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Control output: relay output.
Auxiliary output: 2 points.
Heating wire breakage, SSR fault detection function: single phase heater detection function.
Event input: -.
Communication: RS-485.
Terminal shape: main unit (no terminal unit).
Power supply voltage: AC/DC24V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type OMRON E5CN-Y2HH03T-FLK
E5CN-Y2HH03T-FLK
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating OMRON E5CN-Y2HH03T-FLK.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately).
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8 OMRON E5CN-Y2HH03T-FLK. 5mm). Size: 48 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 4.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV E5CN-Y2HH03T-FLK.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5CN-Y2HH03T-FLK.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.