OMRON E5CN-R2HBTD-W Product information and technical parameters:
Brand: OMRON
Name: Foundation type temperature controller
Model: E5CN-R2HBTD-W
The main body: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: silver.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.

Size: 48 x 48mm.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Auxiliary output: 3 points (common universal).
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: - OMRON E5CN-R2HBTD-W.
Communication: -.
Event input: 2 points.
Remote SP input: there E5CN-R2HBTD-W
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms OMRON E5CN-R2HBTD-W.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermo (sold separately) OMRON E5CN-R2HBTD-W.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication. Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater.
Event entry point: 2.
Transfer output: -.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensorss E5CN-R2HBTD-W.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to eexecute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault