OMRON
Home >> Products >> OMRON >> Temperature controller >> Universal temperature controller >> E5CN-Q2HH03L-FLK | OMRON Foundation type temperature controller E5CN-Q2HH03L-FLK

E5CN-Q2HH03L-FLK | OMRON Foundation type temperature controller E5CN-Q2HH03L-FLK

OMRON E5CN-Q2HH03L-FLK Manual And Instructions
E5CN-Q2HH03L-FLK datasheetPDF datasheet
E5CN-Q2HH03L-FLK datasheetPDF datasheet
E5CN-Q2HH03L-FLK Basic TypeUser's Manual
E5CN-Q2HH03L-FLK User's Manual
E5CN-Q2HH03L-FLK User's Manual
E5CN-Q2HH03L-FLK Communications FunctionsUser's Manual
E5CN-Q2HH03L-FLK USER'S MANUAL
E5CN-Q2HH03L-FLK Communications FunctionsUser's Manual
E5CN-Q2HH03L-FLK USER'S MANUAL

OMRON E5CN-Q2HH03L-FLK Product information and technical parameters:
Brand: OMRON
Name: Foundation type temperature controller
Model: E5CN-Q2HH03L-FLK
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.

Size: 48 x 24mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 2 points.
Power supply voltage: AC/DC24V.
Terminal type: PUSH-IN fastening terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485 OMRON E5CN-Q2HH03L-FLK.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance E5CN-Q2HH03L-FLK
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance OMRON E5CN-Q2HH03L-FLK.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set OMRON E5CN-Q2HH03L-FLK.
It can be easily set by CS-Thermo (sold separately). Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 24 VAC/VDC.
Input type: Thermocouple or resistance thermometer.
Auxiliary outputs: 1.
Control output 1: Relay output.
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous modelss: ±0 E5CN-Q2HH03L-FLK. 5%),
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
mannual, RUN/STOP, and alarms) and the PV or SV E5CN-Q2HH03L-FLK.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.


...More relevant models >>>>