OMRON
Home >> Products >> OMRON >> Temperature controller >> Universal temperature controller >> E5CN-CQ2HHT | OMRON Foundation type temperature controller E5CN-CQ2HHT

E5CN-CQ2HHT | OMRON Foundation type temperature controller E5CN-CQ2HHT

OMRON E5CN-CQ2HHT Manual And Instructions
E5CN-CQ2HHT datasheetPDF datasheet
E5CN-CQ2HHT datasheetPDF datasheet
E5CN-CQ2HHT datasheetPDF datasheet
E5CN-CQ2HHT Basic TypeUser's Manual
E5CN-CQ2HHT User's Manual
E5CN-CQ2HHT User's Manual
E5CN-CQ2HHT Communications FunctionsUser's Manual
E5CN-CQ2HHT USER'S MANUAL
E5CN-CQ2HHT Communications FunctionsUser's Manual
E5CN-CQ2HHT USER'S MANUAL

OMRON E5CN-CQ2HHT Product information and technical parameters:
Brand: OMRON
Name: Foundation type temperature controller
Model: E5CN-CQ2HHT
The main body: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: current output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event input points: -.
Transfer output: output (using control output).
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.

Size: 48 x 96mm.
Type: Platinum resistance.
Adjustment mode: ON/OFF action or PID action.
Alarm: single alarm.
Output: voltage output (for driving SSR).
Temperature controller with single alarm output.
SV and PV can be displayed at the same time.
Multiple temperature range allows setting the optimum temperature range OMRON E5CN-CQ2HHT.
The protection function can prevent the error in operation. The main body: terminal type, temperature input type E5CN-CQ2HHT
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: ES1B power supply OMRON E5CN-CQ2HHT.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type OMRON E5CN-CQ2HHT.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 4.8 dia.
Protective tubing length L: 20 cm.
Lead wire type: Heat resistive.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 48 x 48mm.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Auxiliary output: 2 independent points.
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: -.
Remote SP input: -.
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for aa variety of applications E5CN-CQ2HHT.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermmo (sold separately) E5CN-CQ2HHT.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.


...More relevant models >>>>