With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
The use of communication adapter cable (sold separately) connected with a computer.
Combined temperature control device through component communication.
Size: 48 * 48mm, terminal type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function OMRON E5CC-QX3ASM-004
E5CC-QX3ASM-004
Event input points: -.
Transfer output: -.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0 OMRON E5CC-QX3ASM-004. 01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay) OMRON E5CC-QX3ASM-004.
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Element type: K (CA).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 8 dia.
Protective tubing length L: 75 cm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Control output 1: Linear current output.
Control output 2: --.
Auxiliary output: Three.
Communications: RS-485.
Heater burnout: --.
Event inputs: Two.
Power supply voltage: 100 to 240 VAC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup annd Operation E5CC-QX3ASM-004.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm E5CC-QX3ASM-004.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other.