OMRON E5CC-CX2ASM-005 Product information and technical parameters:
Brand: OMRON
Name: Digital temperature controller
Model: E5CC-CX2ASM-005
Size: 48 x 48mm.
Control output 1: linear current output.
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: 4 points.
Remote SP input: -.
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermo (sold separately).
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.

Size: 1/4 DIN 96 × 96 × 78 (W × H × D).
Power supply voltage: 24 VAC/VDC.
Input type: Thermocouple or Resistance thermometer.
Alarm output: 3.
Control output: Relay output.
Functions: Heater burnout, NO; Mounting option units, Yes.
Previous model: None.
These Best-selling General,
purpose Temperature Controllers,
Are Now Even Better OMRON E5CC-CX2ASM-005.
Controllers now available with analog inputs E5CC-CX2ASM-005
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Manual output provided.
Easy setting with 11-segment displays.
New protocol called Modbus is installed in the,
models with communications OMRON E5CC-CX2ASM-005.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1.6 dia.
Protective tubing length L: 15cm.
Lead wire type: Heat resistive .
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work OMRON E5CC-CX2ASM-005.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automaticc / manual, RUN/STOP, alarm), interactive display PV/SV E5CC-CX2ASM-005.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5CC-CX2ASM-005.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.