Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 6.4 dia.
Protective tubing length L: 50 cm.
Lead wire type: Heat resistive.
Lead wire length M : 2m.
A Wide Variety of High-precision.
Temperature Sensors.
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
and also according to the type and shape of the terminal.
Type: temperature measurement impedance type.
Adjustment mode: ON/OFF action or PID action.
Alarm: there.
Output: relay output.
Digital universal single display electronic temperature controller DIN 48 * 48mm self tuning (self-tuning) PID control. "Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black OMRON E52-IC50AY D=6.4 NETU 2M.
Control output 1: output unit mode.
Control output 2: output unit mode
E52-IC50AY D=6.4 NETU 2M
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products OMRON E52-IC50AY D=6.4 NETU 2M.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors OMRON E52-IC50AY D=6.4 NETU 2M.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type. Control output 1: Relay output.
Control output 2: Relay output.
Auxiliary output: Two.
Communications: --.
Heater burnout: One.
Event inputs: Four.
Power supply voltage: 100 to 240 VAC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operatiion E52-IC50AY D=6.4 NETU 2M.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm E52-IC50AY D=6.4 NETU 2M.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other.