OMRON E52-IC1DY M8 4M Product information and technical parameters:
Brand: OMRON
Name: Temperature Sensor
Model: E52-IC1DY M8 4M
Protective tubing length: M8 screw.
Lead wire length: 4m.
Element type: J (IC).
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal.

Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function OMRON E52-IC1DY M8 4M.
Event entry point: 2.
Transfer output: transfer output (special terminal) E52-IC1DY M8 4M
Remote SP:4 to 20mA input.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0 OMRON E52-IC1DY M8 4M. 01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver OMRON E52-IC1DY M8 4M. 4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Size: 1/8 DIN 48 × 96 × 78(W × H × D).
Power supply voltage: 24 VAC/VDC.
Input type: Thermocouple or Resistance thermometer.
Alarm output: 3.
Control output: Current output.
Functions: Heater burnout, No; Mounting option units, Yes.
Previous model: None.
These Best-selling General,
purpose Temperature Controllers,
Are Now Even Better.
Controllers now available with analog inputs.
Faster samppling at 250 ms E52-IC1DY M8 4M.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Manual output provided.
Easy setting with 11-segment displays.
New protoocol called Modbus is installed in the,
models with communications E52-IC1DY M8 4M.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33.


...More relevant models >>>>