OMRON
Home >> Products >> OMRON >> Temperature controller >> input device >> E52-CA35AF D=3.2 NETU 2M | OMRON Temperature Sensor E52-CA35AF D=3.2 NETU 2M

E52-CA35AF D=3.2 NETU 2M | OMRON Temperature Sensor E52-CA35AF D=3.2 NETU 2M


OMRON E52-CA35AF D=3.2 NETU 2M Product information and technical parameters:
Brand: OMRON
Name: Temperature Sensor
Model: E52-CA35AF D=3.2 NETU 2M
Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 3.2 dia.
Protective tubing length L: 35 cm.
Lead wire type: Heat resistive.
Lead wire length M: 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal.

Classification: Exclusive Models.
Description: Corrosionresistant model.
Temperature range (See note 3.): 0°C to 180°C.
Element type: K (CA).
Conductor type: Nongrounded type.
Class: 2 (0.75).
Protective tubing material: Fluororesin tubing.
Terminal type: Exposed lead wires.
Page: 24.
A Wide Variety of High-precision OMRON E52-CA35AF D=3.2 NETU 2M.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E52-CA35AF D=3.2 NETU 2M
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal OMRON E52-CA35AF D=3.2 NETU 2M. Size: 96 × 96 mm.
Control type: Basic control (1 loop).
Control mode: Single-loop standard control Single-loop heating and cooling control.
Outputs(control/transfer): 2 points: Pulse voltage and Pulse voltage/current.
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 6; Serial communications, RS-485.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity OMRON E52-CA35AF D=3.2 NETU 2M.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When using models with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4.0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation).
DeviceNet Communications.
Data setting and monitoring can be performed without special programming. Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: RS-422.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E52-CA35AF D=3.2 NETU 2M.
Through the infrared port can be carried out from the frront of the communication E52-CA35AF D=3.2 NETU 2M.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.


...More relevant models >>>>