OMRON
Home >> Products >> OMRON >> Master slave station products >> DeviceNet >> DRT2-OD16MLX-1 | OMRON MIL Connector Terminals with Transistors DRT2-OD16MLX-1

DRT2-OD16MLX-1 | OMRON MIL Connector Terminals with Transistors DRT2-OD16MLX-1

OMRON DRT2-OD16MLX-1 Manual And Instructions
DRT2-OD16MLX-1 datasheetPDF datasheet
DRT2-OD16MLX-1 System Manual
DRT2-OD16MLX-1 INSTRUCTION Manual

OMRON DRT2-OD16MLX-1 Product information and technical parameters:
Brand: OMRON
Name: MIL Connector Terminals with Transistors
Model: DRT2-OD16MLX-1
Specifications: Outputs;
PNP (+ common);
16 points.
I/O connections: MIL connector(Connector with 10-cm cable).
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Very Compact 16-/32-point Remote Terminals.
Used in combination with Interface,
Conversion Boards (e.g., D-Sub) to,
connect to a wide range of interfaces.
35 x 60 x 80 mm (W x D x H).

Name: Clamp Terminal Blocks.
Specifications: Outputs; 8 outputs ; NPN; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction OMRON DRT2-OD16MLX-1.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site DRT2-OD16MLX-1
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Name: e-CON Connectors.
Specifications: Outputs; 32 outputs; PNP;
Without Short-circuit and,
Disconnected Line Detection OMRON DRT2-OD16MLX-1.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error OMRON DRT2-OD16MLX-1. Specifications: Outputs; PNP (+ common); 16 points.
I/O connections: MIL connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Very Compact 16-/32-point Remote Terminals.
Used in combination with Interface,
Conversion Boards (e.g., D-Sub) to,
connect to a wide range of interfaces.
35 x 60 x 80 mm (W x D x H). Analog I/O terminal with screw terminal,
block for EtherCAT communicaitons.
The input/output range can be easily,
changed by the setting with the switch.
Detachable screw terminal block,
facilitates the maintenance.
Moving average calculatioon function DRT2-OD16MLX-1.
Settings within the range of 100μs-64ms.
(For input only.)
Disconnection detection function.
(For input only and for usage with,
1-5V or 4-20mA ranges.)
Selectable node address setting methods:
setting with rotary,

switch and with tool software DRT2-OD16MLX-1.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.


...More relevant models >>>>