Number of beams: 103.
Protective height: 1,040mm.
New Standard of Safety Light.
Curtain,Offering Both Robustness.
and Reliability.
Robust and compact.
New muting function to increase both productivity and safety.
All models designed for global use. PNP/NPN selection by.
DIP switch.
Conforming to major international standards including OMRON D4SL-N2BFA.
Chinese standard GB 4584. Compact (104
D4SL-N2BFA5 mm), lightweight (1.3 kg),
and easy-to-install Safety Laser Scanner.
Provides a safety circuit of PLd/Safety Category 3 (ISO13849-1) without a,
dedicated controller.
Type 3 Safety Laser Scanner complies with IEC61496-1/-3.
70 sets of safety zone and warning zone combinations are available,
supporting complicated changes in working environments OMRON D4SL-N2BFA.
A safety radius up to 4 m and warning zone(s) radius up to 15 m can be set.
The minimum object resolution can be changed to 30, 40, 50 or 70 mm.
The response time is configurable from 80 ms to a maximum of 680 ms.
Reference Boundary Monitoring function prevents unauthorized changes in,
the scanner position.
Minimal down time, sensor block can be replaced without the need to reprogram OMRON D4SL-N2BFA. EASY type reduces implementation costs.
with 1/2 the mounting time.
In pursuit of simple functions: Upon detection of personnel,
the machine stops.
Can be used for simple hand intrusion detection.
Implementation costs can be significantly reduced. Lock method: Mechanical lock.
Conduit size: PG13.5.
Voltage for solenoid: 24 VDC.
With LED indicator 1NC/1NO+ 1NC (Slow-action).
Release Protective Cover Locks Using.
Controller Signals or Pushbutton.
Switches after the Cutting Tool Stops.
Moving Due to Inertia.
A mechanical lock is applied automatically when the Operation.
Key is inserted. A high level of safety is achieved using a,
mechanism where the lock is only released when voltage is,
applied to the solenoid.
Conforms to EN (TÜV) standards corresponding to the CE marking.
Certified by UL, CSA and CCC standards.
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened.
Direct opening mechanism that is EN-certified is indicated by,
on the Switch.
Auxiliary release key ensures easy maintenance and unlocks the,
door in the case of a power failure.
Tough aluminum die-cast body incorporating a switch bbox with,
degree of protection satisfying IP67, UL, and CSA TYPE6P, 13 D4SL-N2BFA.
Equipped with a horizontal and vertical conduit opening.
Models incorporating easy-to-see indicators for monitoring and,
those using an adjustable Operation Key ffor a swinging door are available D4SL-N2BFA.
The mounting direction of the head can be changed,
to allow the Operation Key to be inserted from four directions.