I/O Cable (for Rack I/O to Backplane) 0.4 m (L) CV500-CN413I/O Cable (for I/O to Interface Racks) 10 m (L) CV500-CN132CV500-CN Cable Bus Connecting Cable Used to join two Hard Disk Units CV500-CN116.CV500-RM SYSMAC BUS Remote I/O Master Unit (optical) CV500-RM211.
Light type.Model: C500-ETL01.
C500-ET Special I/O Unit Educational Tool I/O Unit C500-ETL01 OMRON CVM1D-BC051. Model : CV500-CN232.
Cable I / O connection
CVM1D-BC051
20m cable length.C500-OD I/O Unit Transistor Output 16 pts C500-OD219.
DC12-24V 2.1A.I/O Cable (for I/O to Interface Racks) 1 m (L) CV500-CN122Model: C500-CN431.
Cable length: 40 m.
Programming Console Connecting Cable.
For extension and connection of FIT of FIT.
Protector for CPU bus connector CV500-COV01Model : CV500-CN432 OMRON CVM1D-BC051.
Cable I / O connection.
40M cable length.C500-AD Special I/O Unit Analog Input C500-AD501.
Input: 16 pts.
Specification: 0~+5V, 0~+10V, -5~+5V
-10~+10V, 0~+20mA, -20~+20mA.C1000H-SL SYSMAC BUS SYSMAC LINK C1000H-SLK21-V1.C500-DA/3G2A5-DA Special I/O Unit Analog Output C500-DA001(3G2A5-DA001).
Output: 2 pts.
Specification: +1~+5V、4~20mA.Model: C500-CN331 OMRON CVM1D-BC051.
Cable length: 30 m.
Programming Console Connecting Cable.
For extension and connection of FIT of FIT.
I/O Control UnitC500-ID Special I/O Unit ID Sensor Unit Long-distance C500-IDS22.Model : C500-PS222-E.
Expansion I/O Backplane Power Supply
100 to 120 VAC or 200 to 240 VAC (selectable).
Output ratings: 7 A, 5 VDC.Model : C500-LK103.
PCF.C500-IM I/O Unit INPUT MODULE 16POINT 24VAC/DC C500-IM211(3G2A5-IM211).
AC/DC12-24V 10mA。The initial configuration of the G language unit in the industry due to the use of G language,
Complex processing procedures do not need to be able to make the ladder diagram.
The realization of the first 1 axis simultaneous control of 4 axis simultaneous control in the industry is due to the multi task function,
Can be executed at the same time or the 2 axis simultaneous control of 4 axes, and then can achieve the 4 axis independent control, etc.
Up to 8 units can be installed CVM1 8 units can be installed 1 units, can control up to 32 axes.
Applicable to ABS encoder by standard,
Applicable to the ABS ttype (absolute output) encoder, so after the emergency stop, no need to search for the origin, etc CVM1D-BC051. .
S curve also according to the standard configuration plus deceleration curve, in addition to the trapezoidal outside,
Also configured too suppress the mechanical vibration of the S shape curve CVM1D-BC051.
Program login maximum of up to 100
G language can be programmed with the MC support software G