OMRON
Home >> Products >> OMRON >> CS1G/CS1H/CS1D/CS1W PLC >> CS1 series PLC high performance I/O unit >> CS1 series process simulation I/O unit >> CS1W-PTR02 | OMRON Process Analog I/O Units CS1W-PTR02

CS1W-PTR02 | OMRON Process Analog I/O Units CS1W-PTR02

OMRON CS1W-PTR02 Manual And Instructions
CS1W-PTR02 datasheetPDF datasheet
CS1W-PTR02 User's Manual

OMRON CS1W-PTR02 Product information and technical parameters:
Brand: OMRON
Name: Process Analog I/O Units
Model: CS1W-PTR02
Unit type: CS1 Special I/O Units.
Product name: Analog Input Unit (100 mV).
Input points : 8 inputs.
Signal range: 0 to 100 mV, ±100 mV.
Conversion speed (resolution):
200ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.08A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.

Name: CS1D CPU Unit for Duplex CPU Systems.
Specifications: Number of I/O points,
5,120 points (7 Racks);
Program capacity, 60 Ksteps;
Data Memory, 128 Kwords,
(DM: 32 Kwords, EM: 32 Kwords×3banks);
LD execution time, 0.02 μs;
Duplex CPUs, OK;
Interrupt functions, --.
Current consumption: 5 V system, 0 OMRON CS1W-PTR02. 82A;
26 V system, --.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables CS1W-PTR02 Name: CS1D Expansion Backplane.
Specifications: Applicable systems,
Duplex CPU, Dual I/O Expansion System only;
Number of Power Supply Units,
2 Units max. (for duplex operation);
Number of I/O Units, 9 Units max.
(Slot number 0 is reserved for an,
I/O Interface Unit) OMRON CS1W-PTR02.
Current consumption: 5V system, 1.21A;
26V system, --.
Standards: UC1, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. Unit type: CS1 Special analog I/O Units.
Product name: Analog Output Units.
Specifications: I/O points, 4 outputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 V to 10 V, 4 to 20 mA;
Resolution, 1/4000 ;
Conversion speed, 1 s/point OMRON CS1W-PTR02.
Externa connection, Removable erminal block.
Current consumption: 5V, 0.13A; 26V, 0.18A.
Standards: UC1, N, CE.
For Various Analog I/Os.
Analog Input Units for converting,
analog input signals into binary data.
Analog Output Units for converting ,
binary data into analog output signals. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 8 inputs.
Signal range selection:
Set separately for each input.
I/O type: R, S, K, J, T, L, B.
Conversion speed: 250 ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 26V, 0.06A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in costt and space compared,
with previous systems CS1W-PTR02.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1W-PTR02.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.


...More relevant models >>>>