Product name: CS1 CPU Backplane.
cannot be connected).
Appli cable CPU Unit: CS1 CPU Unit.
C200H Group-2 High density I/O Unit, No.
Yes; C200H series Special I/O Unit, No.
CPU Bus Units: CS-series CPU Bus Unit, Yes.
26 V system, --.
Standards: U, C, N, L, CE.
Highly Reliable Process Control.
Name: AC Power Supply Unit.
Power supply voltage:
100 to 120 V AC or 200 to 240 V AC.
Output capacity: 5 VDC output capacity, 7A;
26 VDC output capacity, 1.3A;
Total, 35W.
Options: 24 V DC service power supply, No;
RUN output, Yes.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables OMRON CS1W-BC022. Unit type: CS1 Basic I/O Units
CS1W-BC022
Product name: DC Input/Transistor Output Unit.
Specifications: 24 VDC, approx. 5 mA
48 inputs, 12 to 24 VDC, 0.1 A,
48 outputs Sinking.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No.
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No OMRON CS1W-BC022.
Words required: 3 input words and 3 output words.
Current consumption: 5V system, 0.35A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 4 inputs OMRON CS1W-BC022.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100.
Conversion speed (resolution):
100 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.15A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in costt and space compared,
with previous systems CS1W-BC022.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1W-BC022.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.