Unit type: CS-series Special I/O Units.
Product name: Analog Input Units.
Conversion speed, 250 s/point max.
(Settable to 1 ms/point).
Externa connection, Removable terminal block.
Current consumption: 5V, 0.12A; 26V, 0.09A.
Standards: UC1, N, CE.
For Various Analog I/Os.
analog input signals into binary data.
binary data into analog output signals.
Name: CS1D CPU Unit for Duplex CPU Systems.
Specifications: Number of I/O points,
5,120 points (7 Racks);
Program capacity, 60 Ksteps;
Data Memory, 128 Kwords,
(DM: 32 Kwords, EM: 32 Kwords×3banks);
LD execution time, 0.02 μs;
Duplex CPUs, OK;
Interrupt functions, --.
Current consumption: 5 V system, 0 OMRON CS1W-AD041-V1. 82A;
26 V system, --.
Standards: UC1, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables
CS1W-AD041-V1 Unit classifi cation: CS1 CPU Bus Unit.
Product name:Controller Link Unit.
Specifications: Communications cable,
Optical ring GI cabl;
Communications type, Data links and,
message service; Duplex support,
Yes. Unit duplexing and cable loop,
back are supported OMRON CS1W-AD041-V1.
Max. Units mountable per CPU Unit,
Non-duplex: 8, Duplex: 11 (6 Units,
comprising 3 sets of Duplex Units,
+ 5 Non-duplex Units).
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.65A; 26V, --.
Standards: UC1, N, L, CE.
New Controller Link Units,
Now with 4,000 Send Words.
The Controller Link is an,
FA network that can send,
and receive large amounts,
of data easily and at high speed OMRON CS1W-AD041-V1.
The Controller Link supports data,
links that enable sharing data between,
PLCs and computers and a message service,
that enables sending and receiving,
data whenever required.
With Wired Controller Link Units,
systems can be flexibly built by using,
Repeater Units to enable T branches,
long-distance wiring, and converting,
part of the network to optical cable. Unit type: CS1 Special I/O Units.
Product name: Power Transducer Input Unit.
Input points : 8 inputs.
Signal range: 0 to 1 mA, ±1 mA.
Conversion speed (resolution):
200ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.08A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost annd space compared,
with previous systems CS1W-AD041-V1.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1W-AD041-V1.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.