Name: e-CON Connectors.
Disconnected Line Detection.
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
wiring in the system.
contribute to system size reduction.
helps to detect errors on site.
content of the error.
Name: Three-tier Screw Terminal Block.
Specifications: Inputs; 16 inputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system OMRON CRT1-ID16S.
A wide variety of CompoNet Slave Units,
contribute to system size reduction
CRT1-ID16S
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. I/O classification: Input.
Internal I/O circuit common: PNP (– common) OMRON CRT1-ID16S.
I/O points: 8.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC.
Long-distance Communications Supported by SRT2 Models,
(Long-distance/High-speed Communications Selection).
Ultra-compact at 80 x 48 x 50 (W x H x D) mm for,
4-point and 8-point terminals and 105 x 48 x 50,
(W x H x D) mm for 16-point terminals.
Two independent power supplies can be used,
because the I/O terminals are insulated from the internal circuits OMRON CRT1-ID16S.
DIN track mounting and screw mounting are both supported. Specifications: Outputs; NPN (- common);
16 points.
I/O connections: M3 screw terminals.
Rated internal circuit power supply voltage:
Supplied from Basic Unit.
I/O power supply voltage: 24 VDC.
A Smart Slave with a 3-tier Terminal,
Block That Means Wiring Locations,
Are Easy to Understand with No,
Sharing of Terminals.
Easy wiring with no sharing of terminals.
Easy-to-understand wiring locations.
No relay terminal block terminals required.
Detachable cassette-type circuit sections. Short/disconnection detection: Supported.
Specifications: I/O, PNP (input: - common, output: + common), 16 inputs/16 outputs.
I/O connnections: Clamp terminals CRT1-ID16S.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
Reduced Wiring and Labor on Factory Sites with Screw-less Terminal Wiring.
Screw--less structure eliminates tightening work CRT1-ID16S.
Detachable terminal blocks for easier maintenance.
Single-step wiring by simply inserting pole terminals.