Unit: 10 points (6 inputs/4outputs); Connector model.
Inputs: 6 points at 24 VDC.
Outputs: 4 transistor sourcing outputs.
Clock: Yes.
Ultra-compact, Thin-profile CPM2C CPU.
Unit with CompoBus/S Master Offering.
No Complicated Wiring.
applications.
Ultra-compact at 40 x 90 x 65 mm (W x H x D) with.
10 I/O points and CompoBus/S Master offers.
versatile expandability to construct systems.
meeting on-site needs.
system construction cost.
connected. Furthermore, CompoBus/S Remote,
Terminals can be used for expansion I/O points.
simplified. Furthermore, the miniaturization of the,
control panel reduces cable, terminal block, and wiring costs.
Easy System Designing, Modification, and Expan sion.
CompoBus/S Remote Terminals with high-speed.
bus communications and no complicated wiring.
expansion is reserved at the designing stage.
and time stamps. This functionality can be used as,
a weekly timer as well.
Name: Three-tier Screw Terminal Block.
Specifications: Outputs; 8 outputs; PNP;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system OMRON CPM2C-S110C.
A wide variety of CompoNet Slave Units,
contribute to system size reduction
CPM2C-S110C
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Name: System Units; End Unit *2.
Specifications: Necessary for,
terminating the Slice I/O Terminal OMRON CPM2C-S110C.
Standards: CE, UC1, L, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site OMRON CPM2C-S110C.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Unit: Connector model.
I/O classification: Digital input.
Internal I/O common: NPN (+ common).
I/O points: 16.
I/O connections: Molex connector.
Power supplyvoltage: 24 VDC.
I/O specification: DC/transistor.
Digital I/O Units Compatible with MULTIPLE I/O TERMINAL,
Terminal block, connector, and high-density connector,
models are available.
The circuit block of the terminal block model can be,
mounted or dismounted for ease of maintenance without,
disconnecting the wires.
DIN track mounting. I/O classification: Counter Unit.
External I/O points: Inputs: 1, Outputs: 2.
I/OO connections: Terminal block CPM2C-S110C.
Operating mode: Linear counter.
A Counter Unit Supporting Encoder,
Input for Use with MULTIPLE I/O TERMINAL.
High-speed pulse with counting speed of 50 kHz.
Counting can be set to a multiplication faactor of 1 or 4 CPM2C-S110C.
Wide range of measurement: -8,388,608 to 8,388,607.
One external input and two external outputs are available.
DIN track mounting.